![]() | This ![]() It is of interest to the following WikiProjects: | |||||||||||||||||||||||||||
|
"Real gas relations [icon] This section requires expansion. (June 2008)"
... Yes. Yes it does. ;) -- Rei ( talk) 15:36, 23 August 2016 (UTC)
What is the Cv value for Nickel, while the Cp is 460.6 J/Kg-K? — Preceding unsigned comment added by 132.205.16.185 ( talk) 12:48, 30 May 2006
Merger of Heat capacity ratio and Adiabatic index was proposed by Bryan Tong Minh on 11 January 2007.
Merger completed. -- Myth ( Talk) 06:18, 2 March 2007 (UTC)
I am guessing that the tabulated values for the adiabatic index are at atmospheric pressure. If so, I think this should definitely be mentioned somewhere. Does anyone know? 84.12.252.210 15:16, 28 August 2007 (UTC)
I strongly believe that the title of this article should be "Adiabatic index", not "Heat capacity ratio". I'm a student in physics, and I have frequently heard the term adiabatic index thrown around, but never heard heat capacity ratio before. As an objective gauge of the popularity of the terms, a Google search for "adiabatic index" gets 76,000 hits, while "heat capacity ratio" only gets 17,500. One thing that heat capacity ratio has going for it however, is that it is more descriptive. -- Apetre ( talk) 02:53, 5 December 2007 (UTC)
The explanation in the 4th (?) paragraph of this article as to why Cp differs from CV is misleading. It gives the example of comparing the heats required to raise the temperature of a gas under constant pressure versus constant volume conditions, the former involving expansion of the gas, and therefore (positive) work being performed by the gas on the surroundings. This work performed is posited as the reason for the difference in Cp and CV. This is a common and misleading explanation. While this explanation is true for an ideal gas, it is not true in general that the reason for the difference in Cp and CV is solely due to the work performed. The work performed by a substance at constant pressure will be positive or negative, depending upon the sign of the thermal expansion coefficient of the substance, yet it is always true that Cp >= CV for all homogeneous, isotropic, one-component substances subject to only pdV work, so it cannot be that the work performed alone accounts for the difference in Cp and CV. For water between 0 C an 4 C, for example, the thermal expansion coefficient is negative, yet Cp > CV. That Cp >= CV for a homogeneous ... substance is a consequence of the Combined First and Second Laws of Thermodynamics, and is independent of the sign of the thermal expansion coefficient: Cp - CV = TVb2/k (Here b = thermal expansion coefficient & k = isothermal compressibility -- pardon me that I don't know LaTeX). For any homogeneous ... substance, from the First Law of Thermodynamics alone, we have CV = (dU/dT)V and Cp = (dU/dT)p + pVb. For ideal gases, (dU/dT)V = (dU/dT)p = constant = CV, and Cp > CV because b = 1/T > 0, but this is not true in general. In fact, for Cp to be greater than CV for a substance with a negative thermal expansion coefficient, (dU/dT)p must exceed (dU/dT)V. This demonstrates that Cp differs from CV not just on account of the work performed, but also on account of the difference in the temperature variation of internal energy under constant pressure versus constant volume conditions. The amount and especially the polarity of the difference (that Cp is never less than CV for a homogeneous ... substance, even when the work performed by the substance is negative) is a consequence of the Combined First and Second Laws of Thermodynamics. Prfssr ( talk) 23:47, 12 March 2010 (UTC)
There are a number of things to unpack, including the assertion that ideal gases must have constant heat capacity. That’s predicted by the classical equipartition theorem of statistical mechanics, but quantum statistical mechanics shows that a gas can strictly obey Pv=nRT and have a temperature-dependent heat capacity. You might want to have a look at the perfect gas page. KeeYou Flib ( talk) 04:57, 27 March 2022 (UTC)
The article says:
The last statement (use of k) seems contrary to the first (use of gamma or kappa). Which is correct (if either)? Anyone have the ability to consult the reference cited? I'll check the book I have but I can't compare to other engineering or physics fields.
(As far as it goes, in my mechanical engineering thermodynamics courses we used gamma, but doesn't necessarily imply it is the correct standard in that field.)
Dhollm ( talk) 20:39, 21 August 2010 (UTC)
This section states: "The above definition is the approach used to develop rigorous expressions from equations of state (such as Peng-Robinson), which match experimental values so closely that there is little need to develop a database of ratios or Cv values. Values can also be determined through finite difference approximation." We need some proof that this is true. In Chemical process engineering, the 'rigorous' or 'theoretical' k value derived from an Equation of State (e.g. Peng-Robinson) can differ significantly from that used in many other parts of the industry (e.g. valve, compressor and turboexpander sizing). Thus some clarification of which k values are 'correct' and where the experimental data is would be welcome. TriMomma ( talk) 18:47, 13 October 2011 (UTC)
It would be helpful to have a citation of what you are saying here; it could be used to improve the article. KeeYou Flib ( talk) 05:00, 27 March 2022 (UTC)
It is not clear where the extra 2 degrees of freedom come from; what is the source of the equation γ = 1 + 2/f ? Why does expansion of the gas sample correspond to 2 degrees of freedom? — Preceding unsigned comment added by 89.197.3.130 ( talk) 17:18, 27 February 2019 (UTC)
There is no declaration of the significance of the heat capacity ratio in thermodynamics other than its rational quantity, per se. Examples are needed of the utility of cp/cv other than simply 'a method of deriving cv from cp'. — Preceding unsigned comment added by Hippocrocopig ( talk • contribs) 16:26, 16 March 2016 (UTC) Hippocrocopig ( talk) 19:55, 22 March 2016 (UTC)
The stated value of 1.088 does not agree with the general trend of the data and also disagrees with what is given in the German wikipedia. Has anybody got access to the souce books?-- Polis Tyrol ( talk) 10:46, 9 May 2017 (UTC)
And from a theoretical point of view the value should not be lower than 1,28. 134.169.50.143 ( talk) 13:04, 25 January 2018 (UTC)
import cantera as ct
air = ct.Solution('gri30.xml') # thermodynamic file
air.TPX = 2000.0+273.15, 1.0e5, 'N2:0.79, O2:0.21' # set T[K], P[Pa], air composition
print(air.cp/air.cv) # compute gamma
While trying unsuccessfully to find the ISBN for the 10th edition of Lange's handbook (ref 2), I found that the text of the 15th edition has been posted online and it does not contain a listing of specific heat ratio, only of molar . I suspect that the table entries taken from Lange have been calculated using , which, per the article, is not particularly accurate for real gases. It would be great if someone could find the time to replace the table with more accurate and reliably sourced data. PaddyLeahy ( talk) 11:46, 31 March 2020 (UTC)
Somewhat an answer to PaddyLeahy above, but more generally I consider replacing the table with values from https://janaf.nist.gov/ . I want to check if there is strong opposition before doing the copy-pasting, though.
The NIST tables give Cp values. If I read [1] correctly, in particular section 6.1, they used experimental data to fit the constants in ab initio calculations, then ran a fit through the results, and that is what the tables show. Importantly, the calculation make the assumption that gases are ideal.
My feeling is that if we trust NIST data for Cp, we implicitely trust the ideal gas hypothesis baked into them (for the gases, temperature ranges, etc. they give). In that case, we (Wikipedia editors) are not doing WP:OR by using it to compute γ from the source's Cp.
Thoughts? Tigraan Click here to contact me 10:38, 3 April 2020 (UTC)
Under ideal gas relation should a bar be added on top of Cv and Cp since they are molar? (to match notation above it) Rmb87 ( talk) 15:17, 26 March 2022 (UTC)
A. It doesn't follow the trend as a data point (perhaps it's a typo of negative fifteen?)
B. It's listed in the table after 1000 °C, making the table unsorted.
Very suspicious in my opinion.
-- RProgrammer ( talk) 16:12, 9 April 2022 (UTC)
Article mentions in the first paragraph that the heat capacity ratio (gamma) is also known as the isentropic exponent (kappa) for a real gas. This is IMHO misleading. Whereas for an ideal gas, kappa is the same as gamma, for real gases, the two are different. For instance:
gamma | kappa | |
---|---|---|
1 bar 400°C | 1.290 | 1.288 |
200 bar 400°C | 2.355 | 1.293 |
I think kappa deserves a separate treatment, as in a dedicated section in the article. The two properties are often erroneously used interchangeably. -- Hummeling ( talk) 16:54, 15 June 2022 (UTC)
![]() | This ![]() It is of interest to the following WikiProjects: | |||||||||||||||||||||||||||
|
"Real gas relations [icon] This section requires expansion. (June 2008)"
... Yes. Yes it does. ;) -- Rei ( talk) 15:36, 23 August 2016 (UTC)
What is the Cv value for Nickel, while the Cp is 460.6 J/Kg-K? — Preceding unsigned comment added by 132.205.16.185 ( talk) 12:48, 30 May 2006
Merger of Heat capacity ratio and Adiabatic index was proposed by Bryan Tong Minh on 11 January 2007.
Merger completed. -- Myth ( Talk) 06:18, 2 March 2007 (UTC)
I am guessing that the tabulated values for the adiabatic index are at atmospheric pressure. If so, I think this should definitely be mentioned somewhere. Does anyone know? 84.12.252.210 15:16, 28 August 2007 (UTC)
I strongly believe that the title of this article should be "Adiabatic index", not "Heat capacity ratio". I'm a student in physics, and I have frequently heard the term adiabatic index thrown around, but never heard heat capacity ratio before. As an objective gauge of the popularity of the terms, a Google search for "adiabatic index" gets 76,000 hits, while "heat capacity ratio" only gets 17,500. One thing that heat capacity ratio has going for it however, is that it is more descriptive. -- Apetre ( talk) 02:53, 5 December 2007 (UTC)
The explanation in the 4th (?) paragraph of this article as to why Cp differs from CV is misleading. It gives the example of comparing the heats required to raise the temperature of a gas under constant pressure versus constant volume conditions, the former involving expansion of the gas, and therefore (positive) work being performed by the gas on the surroundings. This work performed is posited as the reason for the difference in Cp and CV. This is a common and misleading explanation. While this explanation is true for an ideal gas, it is not true in general that the reason for the difference in Cp and CV is solely due to the work performed. The work performed by a substance at constant pressure will be positive or negative, depending upon the sign of the thermal expansion coefficient of the substance, yet it is always true that Cp >= CV for all homogeneous, isotropic, one-component substances subject to only pdV work, so it cannot be that the work performed alone accounts for the difference in Cp and CV. For water between 0 C an 4 C, for example, the thermal expansion coefficient is negative, yet Cp > CV. That Cp >= CV for a homogeneous ... substance is a consequence of the Combined First and Second Laws of Thermodynamics, and is independent of the sign of the thermal expansion coefficient: Cp - CV = TVb2/k (Here b = thermal expansion coefficient & k = isothermal compressibility -- pardon me that I don't know LaTeX). For any homogeneous ... substance, from the First Law of Thermodynamics alone, we have CV = (dU/dT)V and Cp = (dU/dT)p + pVb. For ideal gases, (dU/dT)V = (dU/dT)p = constant = CV, and Cp > CV because b = 1/T > 0, but this is not true in general. In fact, for Cp to be greater than CV for a substance with a negative thermal expansion coefficient, (dU/dT)p must exceed (dU/dT)V. This demonstrates that Cp differs from CV not just on account of the work performed, but also on account of the difference in the temperature variation of internal energy under constant pressure versus constant volume conditions. The amount and especially the polarity of the difference (that Cp is never less than CV for a homogeneous ... substance, even when the work performed by the substance is negative) is a consequence of the Combined First and Second Laws of Thermodynamics. Prfssr ( talk) 23:47, 12 March 2010 (UTC)
There are a number of things to unpack, including the assertion that ideal gases must have constant heat capacity. That’s predicted by the classical equipartition theorem of statistical mechanics, but quantum statistical mechanics shows that a gas can strictly obey Pv=nRT and have a temperature-dependent heat capacity. You might want to have a look at the perfect gas page. KeeYou Flib ( talk) 04:57, 27 March 2022 (UTC)
The article says:
The last statement (use of k) seems contrary to the first (use of gamma or kappa). Which is correct (if either)? Anyone have the ability to consult the reference cited? I'll check the book I have but I can't compare to other engineering or physics fields.
(As far as it goes, in my mechanical engineering thermodynamics courses we used gamma, but doesn't necessarily imply it is the correct standard in that field.)
Dhollm ( talk) 20:39, 21 August 2010 (UTC)
This section states: "The above definition is the approach used to develop rigorous expressions from equations of state (such as Peng-Robinson), which match experimental values so closely that there is little need to develop a database of ratios or Cv values. Values can also be determined through finite difference approximation." We need some proof that this is true. In Chemical process engineering, the 'rigorous' or 'theoretical' k value derived from an Equation of State (e.g. Peng-Robinson) can differ significantly from that used in many other parts of the industry (e.g. valve, compressor and turboexpander sizing). Thus some clarification of which k values are 'correct' and where the experimental data is would be welcome. TriMomma ( talk) 18:47, 13 October 2011 (UTC)
It would be helpful to have a citation of what you are saying here; it could be used to improve the article. KeeYou Flib ( talk) 05:00, 27 March 2022 (UTC)
It is not clear where the extra 2 degrees of freedom come from; what is the source of the equation γ = 1 + 2/f ? Why does expansion of the gas sample correspond to 2 degrees of freedom? — Preceding unsigned comment added by 89.197.3.130 ( talk) 17:18, 27 February 2019 (UTC)
There is no declaration of the significance of the heat capacity ratio in thermodynamics other than its rational quantity, per se. Examples are needed of the utility of cp/cv other than simply 'a method of deriving cv from cp'. — Preceding unsigned comment added by Hippocrocopig ( talk • contribs) 16:26, 16 March 2016 (UTC) Hippocrocopig ( talk) 19:55, 22 March 2016 (UTC)
The stated value of 1.088 does not agree with the general trend of the data and also disagrees with what is given in the German wikipedia. Has anybody got access to the souce books?-- Polis Tyrol ( talk) 10:46, 9 May 2017 (UTC)
And from a theoretical point of view the value should not be lower than 1,28. 134.169.50.143 ( talk) 13:04, 25 January 2018 (UTC)
import cantera as ct
air = ct.Solution('gri30.xml') # thermodynamic file
air.TPX = 2000.0+273.15, 1.0e5, 'N2:0.79, O2:0.21' # set T[K], P[Pa], air composition
print(air.cp/air.cv) # compute gamma
While trying unsuccessfully to find the ISBN for the 10th edition of Lange's handbook (ref 2), I found that the text of the 15th edition has been posted online and it does not contain a listing of specific heat ratio, only of molar . I suspect that the table entries taken from Lange have been calculated using , which, per the article, is not particularly accurate for real gases. It would be great if someone could find the time to replace the table with more accurate and reliably sourced data. PaddyLeahy ( talk) 11:46, 31 March 2020 (UTC)
Somewhat an answer to PaddyLeahy above, but more generally I consider replacing the table with values from https://janaf.nist.gov/ . I want to check if there is strong opposition before doing the copy-pasting, though.
The NIST tables give Cp values. If I read [1] correctly, in particular section 6.1, they used experimental data to fit the constants in ab initio calculations, then ran a fit through the results, and that is what the tables show. Importantly, the calculation make the assumption that gases are ideal.
My feeling is that if we trust NIST data for Cp, we implicitely trust the ideal gas hypothesis baked into them (for the gases, temperature ranges, etc. they give). In that case, we (Wikipedia editors) are not doing WP:OR by using it to compute γ from the source's Cp.
Thoughts? Tigraan Click here to contact me 10:38, 3 April 2020 (UTC)
Under ideal gas relation should a bar be added on top of Cv and Cp since they are molar? (to match notation above it) Rmb87 ( talk) 15:17, 26 March 2022 (UTC)
A. It doesn't follow the trend as a data point (perhaps it's a typo of negative fifteen?)
B. It's listed in the table after 1000 °C, making the table unsorted.
Very suspicious in my opinion.
-- RProgrammer ( talk) 16:12, 9 April 2022 (UTC)
Article mentions in the first paragraph that the heat capacity ratio (gamma) is also known as the isentropic exponent (kappa) for a real gas. This is IMHO misleading. Whereas for an ideal gas, kappa is the same as gamma, for real gases, the two are different. For instance:
gamma | kappa | |
---|---|---|
1 bar 400°C | 1.290 | 1.288 |
200 bar 400°C | 2.355 | 1.293 |
I think kappa deserves a separate treatment, as in a dedicated section in the article. The two properties are often erroneously used interchangeably. -- Hummeling ( talk) 16:54, 15 June 2022 (UTC)